In transformers, insulation is an important concept that has two different meanings.
Basic Concept of Insulation
In electricity, insulation refers to blocking current in electrical machinery and various electrical or electronic circuits using non-conductors or various components and devices for purposes such as preventing electric shock or separating potentials.
In the field of electricity, the English terms "insulation" and "isolation" are both translated as "zetsuen" (insulation) in Japanese, but they have slightly different meanings depending on their purpose and operating principles.
Two Meanings of Insulation
1. Insulation (insulation)Insulation refers to a state in electronic circuits or their components where the electrical resistance between two target points is high, so that no current flows even when voltage is applied. Even if current does not flow when a low voltage is applied, it may flow when a high voltage is applied; this state is called dielectric breakdown.
2. Insulation (isolation)Insulation (isolation) refers to a state in a part of an electrical or electronic circuit where signals or power are transmitted, but the conductors are separated. Specifically, this refers to two circuits connected via a transformer or photocoupler. In the case of a transformer, power or signals are transmitted via electromagnetic induction, and in the case of a photocoupler, via optical transmission elements. "Isolation" can be said to be a concept close to "separation or segregation."
Characteristics of Insulation in Transformers
Both "insulation" and "isolation" are expressed as "zetsuen" (insulation).
In transformers, the state is electrically insulated (conductors are separated), yet power is transmitted via electromagnetic induction. For this reason, isolation transformers and power transformers are collectively referred to simply as transformers.
Autotransformers are examples of devices that are easily confused with these.
Actual isolation transformer
Product specification example
Case Number 995 (File No. 01-1364)
Three-phase isolation transformer (isolation transformer)
10kVA
50/60Hz
Primary voltage: 200V 28.9A Terminal size M5
Secondary voltage: 200V 28.9A Terminal size M5
Connection: Δ/Δ
With independent terminal for electrostatic shield
The above is reprinted from Wikipedia "Insulation (electricity)".